INDUSTRIAL HEAT TRANSFER FLUIDSTalk to our team · 704-839-6615 ↗
OPEN BATH THERMAL FLUIDS

StaticTherm G open bath fluid

PAG thermal fluid for exposed systems.

PAG thermal fluid for exposed systems.

StaticTherm G is a polyalkylene glycol (PAG)-based thermal fluid intended for demanding oxidation conditions, including open baths. Its published maximum bulk rating is 500°F / 260°C.

Where this grade fits

Consider G when reviewing plastic-processing equipment, die-casting applications, or an exposed bath where air contact challenges fluid life. Describe both the process and the equipment arrangement so suitability can be checked.

Oxidation resistance and fluid condition

The formulation includes antioxidants and other additives intended to help control degradation and deposits. Air exposure, operating temperature, contamination, and the maintenance history remain important to selection and service monitoring.

Compatibility needs a product-specific review

G has a supplier-described compatibility feature for commonly used petroleum-based fluids. This is not a blanket mixing instruction for every charge or application. Identify the exact existing product and confirm the changeover method before adding or replacing fluid.

Information for an application review

  • Bath temperature, exposed surface area, and heater arrangement
  • Parts, construction materials, contaminants, and fluid carryout
  • Current product, system volume, and maintenance history
  • Rinsing or downstream finishing requirements
  • Required quantity, delivery location, and changeover window

Common questions

Is StaticTherm G the same as G-WS?

No. G-WS is a separate water-soluble formulation with its own properties and compatibility limitations.

Is the 500°F bulk rating a recommended bath setpoint?

No. Confirm the allowable operating conditions for the bath, including its exposure, equipment limits, and the separate flash-point and film-temperature data.

Technical data and safety information

Review the current grade-specific properties and confirm the product and operating conditions for your equipment. Request the current SDS before handling or filling.

Download StaticTherm G TDS (PDF, 4 pages) ↓Request the safety data sheet →

Let’s find your next fluid.