INDUSTRIAL HEAT TRANSFER FLUIDSTalk to our team · 704-839-6615 ↗
OPEN BATH THERMAL FLUIDS

StaticTherm S open bath fluid

Silicone thermal fluid for open-bath service.

Silicone thermal fluid for open-bath service.

StaticTherm S is a silicone-based heat transfer fluid intended for exposed processes and strong oxidation resistance. Its TDS distinguishes a 400°F / 204°C open-system bulk limit from a 600°F / 315°C closed-system bulk limit.

Open and closed limits are different

For open-bath selection, use the open-system limit as the relevant published rating. The higher closed-system value is not an open-bath recommendation. Confirm the complete operating envelope for the equipment and its heating arrangement.

Where this grade fits

Applications described in the TDS include annealing and quenching baths, plastic forming, and other exposed processes where oxidation resistance is important. Its wide temperature range can also be relevant to heating-and-cooling duties, subject to system review.

Control contamination and leakage

The supplier identifies S as best suited to applications not prone to contamination or leakage. Describe fluid carryout, possible contamination, and maintenance access when considering a silicone fluid. Confirm compatibility and the cleaning or changeover method for the existing circuit.

Information for an application review

  • Bath temperature, exposed surface area, and heater arrangement
  • Parts, construction materials, contaminants, and fluid carryout
  • Current product, system volume, and maintenance history
  • Rinsing or downstream finishing requirements
  • Required quantity, delivery location, and changeover window

Common questions

Can an open bath use the 600°F rating?

No. The TDS lists 600°F for closed systems and 400°F for open systems. The specific bath must also meet its equipment and operating requirements.

Is S interchangeable with a PAG fluid?

Do not assume that. S is silicone-based, while G and G-WS are PAG-based formulations. Review compatibility and the changeover requirements for the exact products.

Technical data and safety information

Review the current grade-specific properties and confirm the product and operating conditions for your equipment. Request the current SDS before handling or filling.

Download StaticTherm S TDS (PDF, 4 pages) ↓Request the safety data sheet →

Let’s find your next fluid.

Discuss your application ↗